Dynamic Active Power Quality Synthetic Filter Compensator (DAS)
Dynamic Active Power Quality Synthetic Filter Compensator (DAS)
Dynamic Active Power Quality Synthetic Filter Compensator (DAS) is a power compensation system developed by ACTIONPOWER that compensates for reactive power and harmonics in the system simultaneously. This device connects in parallel to the distribution system and continuously monitors the system's current components. Through control computation and logical changes, it calculates the required reactive and harmonic components of the system. Then, through a three-phase full-bridge converter circuit, the device actively generates the necessary reactive and harmonic currents and injects them into the distribution system, achieving intelligent compensation that addresses both reactive power and harmonics. Additionally, the equipment has anti-interference features, does not endanger the distribution system during operation, and offers high stability, reliability, and easy maintenance. The application fields of DAS include industrial power distribution sites such as equipment manufacturing, petrochemical industry, metallurgy, textile industry, building materials industry, light industry, etc., as well as civil architecture industries like data centers, hospitals, large venues, research platforms, high-end buildings, etc.
Parameter
  • Technical Parameters 01
  • Input voltage380V,-30%~﹢20%
  • Input frequency50Hz,±10%
  • Connection mode3P3W/3P4W (compatible with both)
  • Module capacity50kvar/25A、100kvar/50A、150kvar/75A
  • Single cabinet capacity50kvar/25A~1000kvar/500A
  • Response time≤5ms
  • Power loss<3%
  • Compensation functionReactive power, harmonics
  • Compensation rateNot less than 95%
  • CT scan requirements5A, both grid side and load side are possible
  • ProtectionMultiple protection functions such as overcurrent, overheating, over and under voltage protection.
  • IP gradeModule: IP20, complete machine: IP30; higher IP grades for the complete machine can be customized.
  • Ambient temperatureWorking temperature: -10°C ~ 50°C (derating above 40°C);Storage temperature: -25°C ~70℃
  • Ambient humidity≤95% (45°C), no condensation
  • Altitude<2000m; for altitudes over 2000 meters, use according to derating requirements specified in GB/T3859.2
  • Incoming modeWhole cabinet: Top entry line/bottom entry line/through-busbar on top of the cabinet
  • Overall dimensions(W×D×H: mm)Module:50kvar/25A:440mm×560mm×88mm(2U);100kvar/50A:440mm×560mm×145mm(3.3U);150kvar/75A:440mm×560mm×228mm(5.2U);Complete machine: 800 x 1000 x 2200; dimensions of the complete machine can be customized
  • Installation methodModule: rack-mounted or wall-mounted; complete machine: freestanding installation
  • Display screen7-inch touch screen
  • Display contentVoltage, load current, compensating current, grid-side current, voltage distortion rate, current distortion rate, etc.
  • Communication interface and communication modeRS485, LAN, WiFi (optional configuration)
  • Communication protocolModbus Protocol
  • Model