Dynamic Voltage Regulation Equipment (VQC)
Dynamic Voltage Regulation Equipment (VQC)
The Dynamic Voltage Regulation Equipment is a product developed by ACTIONPOWER to manage voltage sags. It can quickly adjust voltage levels, protecting the user's equipment from power quality events such as voltage sags and swells.
Parameter
  • System parameters
  • System capacity30~2500kVA
  • Rated voltage class208V~480V
  • Rated supply frequency50Hz
  • Efficiency of complete machine>98%
  • Connection mode3P4W
  • Circuit structureTri-level
  • Performance indicators
  • Correction capability
  • Three-phase grid voltage sag correctionRestores 60% residual supply voltage to 100%, long-term duration
  • Three-phase grid undervoltage correctionElevates voltage from 60% of rated to 100%, sustained correction
  • Three-phase grid overvoltage correctionReduces voltage from 120% of rated to 100%, sustained correction
  • Phase angle error correctionEquipped
  • Grid voltage unbalance correctionEquipped
  • Grid voltage harmonic correctionCapable of suppressing harmonics up to the 25th order.
  • Start threshold range-10%~+10% (adjustable)
  • Voltage regulation precision<2%
  • Fault bypassEquipped
  • Maintenance bypassOptional
  • Compensation response time<700us
  • Total response time<2ms
  • Voltage distortionUnder the condition of a linear load, THDu<3%
  • Protection functionImproved module protection function
  • Human-machine interaction
  • Display screen7-inch color touch screen
  • Parameter settings and data displayOperating status, main wiring diagram, operation log, electrical parameter data, fault record, etc.
  • Incident and data loggingEquipped with event and data recording functions
  • Communication interfaceEthernet/RS485/GPRS/Dry Contact
  • Communication protocolModbus Protocol
  • Mechanical characteristics
  • Combination modeWhole cabinet style, cabinet color (RAL7035) / or as customized by the customer
  • Incoming modeBottom in/bottom out, or as customized by the customer
  • Load requirements
  • Load power factor0.5 (lag) ~ 0.9 (lead)
  • Environmental requirements
  • AltitudeWhole cabinet style <2000m; for altitudes over 2000 meters, use according to derating requirements specified in GB/T3859.2 (1% power reduction for every 100m increase)
  • Operating temperature
  • Relative humidity<95%, no condensation
  • IP gradeIP20, other protection levels can be customized
  • Pollution grade2
  • Noise<65db
  • Cooling modeAir cooling
  • Standards to be followed
  • StandardDL/T1229-2013 Dynamic Voltage Restorer Technical Specifications SemiF47